Rancang Bangun Automatic Transfer Switch (ATS) (Analisa Uninterruptible Power Supply ( UPS )

Ritonga, Sarman (2017) Rancang Bangun Automatic Transfer Switch (ATS) (Analisa Uninterruptible Power Supply ( UPS ). Undergraduate thesis, Politeknik Negeri Bengkalis.

[img]
Preview
Text (Abstract)
TA-3204131027-ABSTRACT.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (90kB) | Preview
[img]
Preview
Text (Bab I Pendahuluan)
TA-3204131027-BAB I.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (174kB) | Preview
[img]
Preview
Text (Daftar Pustaka)
TA-3204131027-DAFTAR PUSTAKA.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (90kB) | Preview
[img] Text (Full Text)
TA-3204131027-FULL TEXT.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.

Download (3MB) | Request a copy

Abstract

The existence of electrical energy is already something of a primary need in modern human life so that almost all people rely on electricity supply from PLN. It can not be denied that the availability of electrical energy from PLN can be guaranteed 100%, many obstacles that cause cessation of electricity supply to consumers. Both the system generator and the distribution network system, Based on the above background, the author tries to create a system that can provide the needs in electrical energy. In the hope that this system can be useful to the general public. Making this ATS Has been done for 4 months in the Department of Electrical Engineering is the focus of this ATS discussion is UPS. The current supplying the UPS load is capable of storing the current when PLN is turned on and when PLN is turned off it can supply current to the load and Provide 60 seconds of time to immediately turn on the generating set instead of electricity from PLN. Provide ample time to immediately back up and secure [OS] (OS) by performing a shutdown according to the procedure when the main power outages.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsEmailNIDN/NIDK
Thesis advisorFaizal, Wan Muhammadwanfaizal@polbeng.ac.idNIDN1003047401
Uncontrolled Keywords: Electrical Energy, ATS, UPS, Genset
Subjects: 410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 451 Teknik Elektro
410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 452 Teknik Tenaga Elektrik
410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 454 Teknik Elektronika
Divisions: Jurusan Teknik Elektro > Sarjana Terapan Teknik Listrik > TUGAS AKHIR