Pengujian Geser Balok Beton Bertulang Dengan Penambahan Baja Ringan

Husna, Rosyidatul (2022) Pengujian Geser Balok Beton Bertulang Dengan Penambahan Baja Ringan. Undergraduate thesis, Politeknik Negeri Bengkalis.

[img]
Preview
Text (Abstract)
SKRIPSI-4204181195-Abstrak.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (266kB) | Preview
[img]
Preview
Text (Bab I Pendahuluan)
SKRIPSI-4204181195-Bab 1.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (391kB) | Preview
[img]
Preview
Text (Daftar Pustaka)
SKRIPSI-4204181195-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (482kB) | Preview
[img] Text (Full Text)
SKRIPSI-4204181195-Full Text 1.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.

Download (6MB)

Abstract

Structurally, concrete does not have a large enough strength, especially in withstanding the shear forces due to flexing, so it needs bending looping and shear repeating, which serves to carry the load of concrete blocks. Due to large loadings, it requires considerable dimensions, but these large dimensions have limitations. It is characterized by the distance between the beams on that bridge that is too close, so that the bridge requires beams that have greater strength. To increase the capacity of the beam, this study tried to add mild steel as a shear provider in the hope that there would be an increase in shear capacity with the specified dimensions. As it is known that mild steel has a tensile strength that is almost equal to the tensile strength of steel. The melting stress of mild steel reaches 542.8 Mpa and the maximum voltage reaches 544.01 Mpa. Shear testing is carried out by applying a one-point load to the center of the beam span with a fulcrum distance of 0.60 m. beam test objects are made with a size of 0.15 x 0.25 x 0.86 m and mild steel is made a zinc model with a size of 5 x 20 x 0.7 mm on the reinforcement of the beam. The results of research and analysis using mild steel there is an increase in the capacity of the shear load that can be held by the beam. The maximum load of the control beam is 262 kN with a deflection of 6.87 mm while its maximum load sliding beam is 292 kN and the deflection is 9.3 mm. thus, the load capacity increased by 13.74% and the deflection that occurred in the sliding beam was 31% greater than the control beam.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsEmailNIDN/NIDK
Thesis advisorPuluhulawa, Indriyaniindriyani_p@polbeng.ac.idNIDN0025108603
Uncontrolled Keywords: Shear Testing, Mild Steel, Reinforced Concrete Beam
Subjects: 410 ILMU TEKNIK > 420 TEKNIK SIPIL DAN PERENCANAAN TATA RUANG > 429 Bidang Teknik Sipil Lain Yang Belum Tercantum
Divisions: Jurusan Teknik Sipil > Sarjana Terapan Teknik Perancangan Jalan Dan Jambatan > TUGAS AKHIR
Depositing User: TPJJ 2022
Date Deposited: 06 Sep 2022 16:18
Last Modified: 06 Sep 2022 16:18
URI: http://eprints.polbeng.ac.id/id/eprint/6946

Actions (login required)