Ramadhan, Muhammad Nuzul (2023) Pengaruh Pengurangan Jumlah Air Pada Beton Dengan Penambahan Polynex HE. Diploma thesis, Politeknik Negeri Bengkalis.
|
Text (Abstract)
TA-4103201358-Abstract.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (2MB) | Preview |
|
|
Text (Bab I Pendahuluan)
TA-4103201358-Bab I Pendahuluan.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (685kB) | Preview |
|
|
Text (Daftar Pustaka)
TA-4103201358-Daftar Pustaka.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (471kB) | Preview |
|
Text (Full Text)
TA-4103201358-Full Text.pdf - Submitted Version Restricted to Registered users only Available under License Creative Commons Attribution Share Alike. Download (11MB) |
Abstract
This study aims to determine the behavior of using Polynex HE in concrete mixtures. That from the other side the results of high-quality concrete work fas (cement water factor) must be low or the amount of water is small so that workability is low or difficult. The resulting concrete will also experience the emergence of air cavities even though the concrete has been compacted concrete. For this reason, added materials are needed, one of which is polynex HE. The method used in this test is by making a concrete mixture using SNI 7656: 2012 with Polynex HE as an added material to the concrete mixture by 1% of the weight of cement and a reduction in the amount of water 10%, 15%, 20%, 30% of the amount of normal concrete water. Treated concrete for 1 day, 3 days, 7 days, and 28 days. The parameters to be obtained in this study are the slump value, fill weight and concrete quality. From the test results, the slump value is obtained, the greater the reduction in the amount of water, the smaller the slump value obtained. As for the weight of the contents, the greater the reduction in the amount of water, the smaller the weight of the contents obtained. For concrete quality at the age of 28 days, compressive strength values range from 26.80 – 37.99 Mpa with a maximum value of 37.99 Mpa at BP1-30%.
Item Type: | Thesis (Diploma) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
||||||||
Uncontrolled Keywords: | Concrete Quality, Slump Value, Fill Weight, Polynex HE, Job Mix | ||||||||
Subjects: | 410 ILMU TEKNIK > 420 TEKNIK SIPIL DAN PERENCANAAN TATA RUANG > 421 Teknik Sipil | ||||||||
Divisions: | Jurusan Teknik Sipil > Diploma Tiga Teknik Sipil > TUGAS AKHIR | ||||||||
Depositing User: | Teknik Sipil D3 | ||||||||
Date Deposited: | 15 Aug 2023 10:30 | ||||||||
Last Modified: | 15 Aug 2023 10:30 | ||||||||
URI: | http://eprints.polbeng.ac.id/id/eprint/9171 |
Actions (login required)
View Item |