Waruwu, Yakhin Yaman (2026) Analisa Menentukan Titik Kerusakan Pada Elektro Motor Pompa Celup Di Wp 8 Menggunakan Alat Ukur Meger Dan Multi Meter Di Pt. Indah Kiat Pulp And Paper Perawang Tbk. Other thesis, Politeknik Negeri Bengkalis.
TA.3204221463-Abstrak.pdf - Draft Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (200kB) | Request a copy
TA.3204221463-Bab I Pendahuluan.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (224kB) | Request a copy
TA.3204221463-Daftar Pustaka.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (177kB) | Request a copy
Ta 320422143 Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (6MB) | Request a copy
Abstract
The submersible pump electric motor is a critical component in the paper production process at PT. Indah Kiat Pulp and Paper Perawang Tbk, particularly in the wire section and press section of the paper machine. Continuous 24-hour operation makes the motor susceptible to failures, requiring an effective early fault detection method. This study aims to analyze faults in a 30 kW, 1450 RPM
submersible pump electric motor using a Megger (Insulation Resistance Tester) and a Digital Multimeter. The research employed a quantitative descriptive method with a case study approach, including visual inspection, insulation resistance measurement, winding resistance testing, and operational voltage and current measurements. The results showed that the insulation resistance was below the recommended standard (>100 MΩ), indicating insulation degradation caused by moisture. Winding resistance measurements revealed an imbalance in phase T, indicating a turn-to-turn short circuit, which was supported by overcurrent conditions and visual evidence of brownish marks and condensation inside the motor terminal box. The motor failure was caused by insulation deterioration and a stator winding short circuit. It is recommended to perform motor rewinding or replacement, improve moisture protection in the terminal box, and conduct periodic insulation resistance testing every 3–6 months.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | electro motor, submersible pump, insulation resistance, multimeter |
| Subjects: | 600 – ILMU TEKNIK DAN ILMU TERAPAN > 625 – Teknik Kelistrikan dan Elektronik > 625.9 – Perawatan dan Perbaikan Peralatan Listrik 600 – ILMU TEKNIK DAN ILMU TERAPAN > 625 – Teknik Kelistrikan dan Elektronik > 625.8 – Energi Terbarukan dan Teknologi Listrik Hijau 600 – ILMU TEKNIK DAN ILMU TERAPAN > 625 – Teknik Kelistrikan dan Elektronik > 625.6 – Instrumentasi dan Pengukuran Listrik |
| Divisions: | Jurusan Teknik Elektro > Sarjana Terapan (D-IV) Teknik Listrik > SKRIPSI |
| Depositing User: | TEKNIK LISTRIK 2022 Kelas A |
| Date Deposited: | 14 Aug 2026 09:41 |
| Last Modified: | 14 Aug 2026 09:41 |
| URI: | https://eprints.polbeng.ac.id/id/eprint/6194 |