Analisis Proteksi Gfr Dan Ocr Pada Penyulang Kroasia Menggunakan Software Etap Di PT. PLN (Persero) UP3 Dumai ULP Dumai Kota

Patar, Arif Rahman (2026) Analisis Proteksi Gfr Dan Ocr Pada Penyulang Kroasia Menggunakan Software Etap Di PT. PLN (Persero) UP3 Dumai ULP Dumai Kota. Other thesis, Politeknik Negeri Bengkalis.

[thumbnail of Abstract] Text (Abstract)
1. TA-3204221485-Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (384kB)
[thumbnail of Bab I Pendahuluan] Text (Bab I Pendahuluan)
2. TA-3204221485-Bab I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (292kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
3. TA-3204221485-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (278kB)
[thumbnail of Full Text] Text (Full Text)
4. TA-3204221485-Full Text8811.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (1MB) | Request a copy

Abstract

The Kroasia Feeder is a 20 kV distribution feeder operated by PT. PLN (Persero) UP3 Dumai ULP Dumai Kota that has experienced several faults, causing the Overcurrent Relay (OCR) and Ground Fault Relay (GFR) to trip. This study aims to analyze short-circuit fault currents and evaluate the OCR and GFR settings on the main line of the Kroasia Feeder using manual calculations and ETAP simulations. The analysis was conducted at five fault locations along a 7.939 km stretch. Manual calculations show maximum fault currents of 5,007.38 A for three-phase, 4,336.51 A for two-phase, and 285.87 A for single-phase to ground, while the ETAP results are 5,383 A, 4,662 A, and 286 A, respectively. The calculation results for the settings yielded an OCR of 247.8 A with a TMS of 0.13 and a GFR of 27.2 A with a TMS of 0.1. Compared to the existing settings, these results indicate that the OCR and GFR settings are still appropriate for the analyzed load and fault conditions.

Item Type: Thesis (Other)
Uncontrolled Keywords: OCR, GFR, ETAP, short-circuit fault current, Kroasia Feeder
Subjects: 600 – ILMU TEKNIK DAN ILMU TERAPAN > 625 – Teknik Kelistrikan dan Elektronik > 625.2 – Sistem Tenaga Listrik dan Distribusi
Divisions: Jurusan Teknik Elektro > Sarjana Terapan (D-IV) Teknik Listrik > SKRIPSI
Depositing User: TEKNIK LISTRIK 2022 Kelas A