Analisis Kinerja Mesin Pendingin (AC) Menggunakan Refrigeran Ramah Lingkungan

Leonardo, Leonardo (2026) Analisis Kinerja Mesin Pendingin (AC) Menggunakan Refrigeran Ramah Lingkungan. Diploma thesis, Politeknik Negeri Bengkalis.

[thumbnail of Abstract] Text (Abstract)
1.TA-5497152737-Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (146kB)
[thumbnail of Bab I Pendahuluan] Text (Bab I Pendahuluan)
2.TA-5497152737-Bab I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (189kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
3.TA-5497152737-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (142kB)
[thumbnail of Full Text] Text (Full Text)
4.TA-5497152737-Full leonardo.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (2MB)

Abstract

R32 refrigerant is still widely used in Air Conditioning (AC) systems despite its relatively high Global Warming Potential (GWP), thus requiring a more environmentally friendly refrigerant alternative such as R290. This study aims to compare the performance of an AC system using R32 and R290 refrigerants, evaluated in terms of system working pressure and temperature, cooling capacity, Coefficient of Performance (COP), electrical power consumption, and system efficiency. The experiment was conducted on the same AC unit, operating both refrigerants alternately for 60 minutes, with data recorded at 10-minute intervals. The measured data included low- and high-side pressure, evaporator temperature, condenser temperature, air flow velocity, and electrical parameters. Cooling capacity was calculated using the air-side approach, while COP and system efficiency were determined based on the ratio of cooling capacity to the electrical power consumed by the compressor. The results show that R290 operated at a lower system pressure compared to R32, producing an average cooling capacity of 0.710 kW compared to 0.678 kW for R32, with a lower average power consumption of 866.0 Watts compared to 963.3 Watts for R32. The average COP of R290 was 0.811 with a system efficiency of 81.04%, both higher than R32, which recorded 0.698 and 69.84%, respectively. Based on these results, it can be concluded that R290 refrigerant exhibits better performance than R32, making it a viable alternative to conventional refrigerants for AC systems.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: refrigerant, R32, R290, cooling capacity, COP, system efficiency
Subjects: 600 – ILMU TEKNIK DAN ILMU TERAPAN > 620 – Teknik Mesin dan Teknik Industri > 620 – Teknik Mesin dan Teknik Industri > 620.2 Mesin dan Peralatan Mesin
600 – ILMU TEKNIK DAN ILMU TERAPAN > 620 – Teknik Mesin dan Teknik Industri > 620 – Teknik Mesin dan Teknik Industri > 620.3 Mekanika Fluida
600 – ILMU TEKNIK DAN ILMU TERAPAN > 620 – Teknik Mesin dan Teknik Industri > 620 – Teknik Mesin dan Teknik Industri > 620.4 Termodinamika
Divisions: Jurusan Teknik Mesin > Sarjana Terapan (D-IV) Teknik Mesin Produksi dan Perawatan > SKRIPSI
Depositing User: TMPP 2022 Kelas C
Date Deposited: 27 Aug 2026 03:28
Last Modified: 27 Aug 2026 03:28
URI: https://eprints.polbeng.ac.id/id/eprint/6892