Efektivitas Penggunaan Consol P200-R1 S Sebagai High Range Water Reducer (HRWR) Pada Campuran Beton Dengan Variasi Kadar Air

Sari, Shely Meylinda (2026) Efektivitas Penggunaan Consol P200-R1 S Sebagai High Range Water Reducer (HRWR) Pada Campuran Beton Dengan Variasi Kadar Air. Diploma thesis, Politeknik Negeri Bengkalis.

[thumbnail of Abstrak] Text (Abstrak)
TA-4103230004-Abstrak.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (288kB)
[thumbnail of Bab I Pendahuluan] Text (Bab I Pendahuluan)
TA-4103230004-BAB I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (123kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
TA-4103230004-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (122kB)
[thumbnail of Full Text] Text (Full Text)
TA-4103230004-Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (7MB)

Abstract

This study aims to analyze the effectiveness of using the High Range Water Reducer (HRWR) additive Consol P200-R1 S in concrete mixtures with water content variations on slump value, unit weight, and compressive strength. A laboratory experimental method was conducted using a fixed dosage of 0.8% Consol P200-R1 S by weight of cement, with water reduction variations of 0%, 30%, 40%, and 50%, alongside normal concrete as a control. Cylindrical specimens (15 cm x 30 cm) were tested for compressive strength at 1, 3, and 28 days according to SNI standards. The results showed that the highest slump flow was achieved by the mixture with 0.8% Consol without water reduction (430 mm). All variations met normal-weight concrete criteria, with unit weights ranging from 2,278 to 2,395 kg/m³. At 28 days, adding 0.8% Consol without water reduction decreased compressive strength to 14.88 MPa compared to normal concrete (20.43 MPa). However, combining 0.8% Consol with water reduction significantly increased compressive strength, reaching a peak of 40.13 MPa at 50% water reduction. This study concludes that Consol P200-R1 S effectively enhances concrete compressive strength when combined with optimal water reduction.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Keywords : Concrete, Superplasticizer, Consol P200-R1 S, Compressive Strength, Water Reduction.
Subjects: 600 – ILMU TEKNIK DAN ILMU TERAPAN > 624 – Teknik Sipil dan Konstruksi > 624.1 – Perencanaan dan Desain Bangunan
600 – ILMU TEKNIK DAN ILMU TERAPAN > 624 – Teknik Sipil dan Konstruksi > 624.2 – Struktur Bangunan dan Material
Divisions: Jurusan Teknik Sipil > Diploma Tiga (D-III) Teknik Sipil > TUGAS AKHIR
Depositing User: D-III TEKNIK SIPIL 2023 Kelas A
Date Deposited: 27 Aug 2026 08:29
Last Modified: 31 Aug 2026 07:21
URI: https://eprints.polbeng.ac.id/id/eprint/6998

Actions (login required)

View Item
View Item