Ridhosaputra, Rizki (2024) Penambahan Inverter Pada Modul Motor Penggerak Chain Conveyor Area Balling Line Unit Pupl Dryer Di PT. Indah Kiat Pulp & Paper Tbk. PERAWANG. Undergraduate thesis, Politeknik Negeri Bengkalis.
Text (Abstract)
TA-3204201346-Abstrak.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (14kB) |
|
Text (Bab I Pendahuluan)
TA-3204201346-Bab I Pendahuluan.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (534kB) |
|
Text (Daftar Pustaka)
TA-3204201346-Daftar Pustaka.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (153kB) |
|
Text (Full Text)
TA-3204201346-Full Text.pdf - Submitted Version Restricted to Registered users only Available under License Creative Commons Attribution Share Alike. Download (4MB) | Request a copy |
Abstract
The system for controlling and observing motor conditions on the Chain Conveyor Balling Line Pulp Dryer using an Inverter is a tool that controls motor speed by regulating the frequency (HZ) on the motor by adjusting the parameters contained in the Inverter. The purpose of adding an inverter to the motor module driving the Chain Conveyor Balling Line Pulp Dryer is to reduce surge currents at the start and provide softstart and softstop to the motor so that it can maintain and extend the lifetime of electrical components due to surge currents. Apart from using an inverter, this chain conveyor also uses a Programmable Logic Controller (PLC) and Human Machine Interface (HMI) which makes it easier for users to operate. After conducting research, it is known that the frequency of the Inverter parameter is 17 Hz so the speed of the motor is 510 Rpm. Apart from that, the motor also experiences soft start and soft stop using an inverter starting from 0 - 11.8 A on conveyor 009 and 0 - 9.6 A on conveyor 010, while not using an inverter frequency on the motor, namely 50 Hz with a motor speed of 1400 Rpm and a current on The motor experiences a surge at starting of 23.7 A (nominal 12 A) on conveyor 009 and 17.8 A (nominal 10 A) then the current drops back to the nominal current on the motor.
Item Type: | Thesis (Undergraduate) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
||||||||
Uncontrolled Keywords: | Conveyor, Inverter, Programmable Logic Controller (PLC) , Human Machine Interface (HMI). | ||||||||
Subjects: | 410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 451 Teknik Elektro | ||||||||
Divisions: | Jurusan Teknik Elektro > Sarjana Terapan Teknik Listrik > TUGAS AKHIR | ||||||||
Depositing User: | D4 Teknik Listrik B | ||||||||
Date Deposited: | 21 Aug 2024 10:07 | ||||||||
Last Modified: | 21 Aug 2024 10:07 | ||||||||
URI: | http://eprints.polbeng.ac.id/id/eprint/13055 |
Actions (login required)
View Item |