Monitoring Over Under Voltage Generator Pada Perubahan Beban

Amirul, Rezza (2021) Monitoring Over Under Voltage Generator Pada Perubahan Beban. Undergraduate thesis, Politeknik Negeri Bengkalis.

[img]
Preview
Text (Abstract)
TA-3204171140-Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (150kB) | Preview
[img]
Preview
Text (Daftar Pustaka)
TA-3204171140-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (271kB) | Preview
[img]
Preview
Text (Bab I Pendahuluan)
TA-3204171140-BAB I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (124kB) | Preview
[img] Text (Full Text)
TA-3204171140-Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.

Download (6MB)

Abstract

Abstract – In this study, the author designed a monitoring system for Over/Under voltage Generator on load changes. The quality of electric power in an electrical circuit system is very necessary. Poor quality power supply can cause interference and even damage the equipment system or electrical circuit. One form of interference is the occurrence of under/over voltage. To overcome this, a protective device is needed that can detect under/over voltage disturbances and secure electrical equipment. Under/over voltage relays are designed to detect under/over voltage disturbances at single-phase and 3-phase voltages of 220 V 50 Hz. The voltage limit for under- voltage disturbance is -5% of the normal voltage of 220 V, while over-voltage disturbance is +5% of the normal voltage. And the delay setting for under/over voltage relay is 5 seconds. The output of the relay is connected to the load, the load will be cut off in the event of an Over/Under voltage disturbance.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsEmailNIDN/NIDK
Thesis advisorAbidin, Zainalzainalabidin@polbeng.ac.idNIDK1018086901
Uncontrolled Keywords: Generator Sinkron 3 phasa, protection relay SINOTIMER SVP-916
Subjects: 410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 451 Teknik Elektro
Divisions: Jurusan Teknik Elektro > Sarjana Terapan Teknik Listrik > TUGAS AKHIR
Depositing User: Users 332 not found.
Date Deposited: 21 Sep 2021 12:53
Last Modified: 21 Sep 2021 14:48
URI: http://eprints.polbeng.ac.id/id/eprint/1696

Actions (login required)

View Item View Item