Rini, Endang Setio (2022) Analisa Dan Rancang Bangun Alat Pendeteksi Gangguan Fuse Cut Out (FCO) Melalui Notifikasi Telegram Berbasis Global Positioning System (GPS). Undergraduate thesis, Politeknik Negeri Bengkalis.
There is a more recent version of this item available. |
|
Text (Abstrak)
TA-3204181183-ABSTRAK.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (14kB) | Preview |
|
|
Text (Bab I Pendahuluan)
TA-3204181183-BAB I PENDAHULUAN.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (397kB) | Preview |
|
|
Text (Daftar Pustaka)
TA-3204181183-DAFTAR PUSTAKA.pdf - Submitted Version Available under License Creative Commons Attribution Share Alike. Download (389kB) | Preview |
|
Text (Full Text)
TA-3204181183-Full Text.pdf - Submitted Version Restricted to Registered users only Available under License Creative Commons Attribution Share Alike. Download (5MB) | Request a copy |
Abstract
The electric power system must be able to provide a continuous supply of electrical energy with a standard amount of voltage and frequency in accordance with applicable regulations and the system must immediately return to normal conditions if the system experiences a disturbance. This tool is made to detect disturbances and the location of the fuse cut out (FCO) using the PZEM-004T sensor to read the voltage of each phase and the Neo-6M GPS to get the coordinates of the location to be accessed via Google Map, then the Telegram bot will send a message status information feeder , the coordinates of the location connected to the Google Map, the complete address of the transformer and the voltage value after the FCO fault. The PZEM-004T sensor reads voltages ranging from 80-250 V AC. The difference in the distance between the initial coordinates to the coordinates recorded using GPS Neo-6M and GPS Coordinates is the largest, 8.6 M, while the smallest is 0.09 M. Testing of the equipment was carried out with PT. Adra Gemilang Rayon Bengkalis at PHB-TR PBG015-50 KV. The result of this test is that the Telegram bot sends a message if the FCO in the S phase is decided, namely the S phase status is lost because the voltage in the S phase decreases from 221.9 V AC to 117.7 V AC.
Item Type: | Thesis (Undergraduate) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
||||||||
Uncontrolled Keywords: | Reliability, Fuse Cut Out (FCO), PZEM-004T Sensor, Telegram | ||||||||
Subjects: | 410 ILMU TEKNIK > 450 TEKNIK ELEKTRO DAN INFORMATIKA > 451 Teknik Elektro | ||||||||
Divisions: | Jurusan Teknik Elektro > Sarjana Terapan Teknik Listrik > TUGAS AKHIR | ||||||||
Depositing User: | TEKNIK LISTRIK | ||||||||
Date Deposited: | 26 Aug 2022 16:53 | ||||||||
Last Modified: | 26 Aug 2022 16:53 | ||||||||
URI: | http://eprints.polbeng.ac.id/id/eprint/5722 |