Andrianto, Fuji (2025) Pengaruh Vibrasi Tinggi Dan Rekomendasi Perbaikan Pompa Gland Fan-B Tg 25 Pt. Ikpp Perawang. Other thesis, Politeknik Negeri Bengkalis.
![[thumbnail of Abstrak]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
1.TA-2204211299 -ABSTRAK.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (1MB)
![[thumbnail of Bab I Pendahuluan]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
2.TA-2204211299 -BAB I PENDAHULUAN.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (1MB)
![[thumbnail of Daftar Pustaka]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
3.TA-2204211299 -DAFTAR PUSTAKA.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (1MB)
![[thumbnail of Full Text]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
4.TA-2204211299 -FULL TEXT.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (2MB) | Request a copy
Abstract
This study was conducted to analyze the effect of high vibration on the performance of the Gland Fan-B TG 25 pump at PT. Indah Kiat Pulp & Paper Tbk Perawang, and to provide appropriate repair recommendations to restore the pump's operational condition to optimal levels. Based on the results of monitoring using SKF Vibration and VibXpert tools, a significant increase in vibration values was found, especially in the horizontal and vertical directions. Further inspection by the MEU team identified an imbalance in the impeller and loose bolts on the casing or support. As a follow-up, a dynamic balancing process was carried out which successfully reduced the vibration amplitude from 3,625 mm/s to 0,626 mm/s after the installation of corrective loads. These results indicate that imbalance is the main cause of high vibration. Regular vibration monitoring has proven effective in early detection of potential damage and supporting preventive maintenance programs in industrial environments.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | High vibration, Gland Fan pump, unbalance, balancing, predictive maintenance. |
Subjects: | 600 – ILMU TEKNIK DAN ILMU TERAPAN > 620 – Teknik Mesin dan Teknik Industri > 620 – Teknik Mesin dan Teknik Industri > 620.5 Suara dan Getaran; Kontrol Suara |
Divisions: | Jurusan Teknik Mesin > Sarjana Terapan (D-IV) Teknik Mesin Produksi dan Perawatan > SKRIPSI |
Depositing User: | D-IV TMPP Kelas A 2021 |
Date Deposited: | 18 Aug 2025 07:17 |
Last Modified: | 18 Aug 2025 07:17 |