Sugara, Ravi Ramadhani (2025) Studi Eksperimental Uji Lekatan Antara Tulangan GFRP Dengan Beton. Other thesis, Politeknik Negeri Bengkalis.
![[thumbnail of Abstract]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
1.SKRIPSI-4204211426-Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (330kB)
![[thumbnail of Bab I Pendahuluan]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
2.SKRIPSI-4204211426-Bab I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (365kB)
![[thumbnail of Daftar Pustaka]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
3.SKRIPSI-4204211426-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (347kB)
![[thumbnail of Full Text]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
4.SKRIPSI-4204211426-Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (4MB) | Request a copy
Abstract
This study aims to evaluate and compare the bond strength between Glass Fiber Reinforced Polymer (GFRP) reinforcement and conventional steel rebar in concrete. Experimental tests were conducted using the pull-out and flexural bonding methods based on ACI and SNI standards. GFRP was selected due to its corrosion resistance and lightweight properties, making it ideal for harsh environments such as the coastal region of Bengkalis. Concrete with a compressive strength
of f’c 25 MPa was tested at 28 days of age using bond lengths of 5db, 10db, and 15db. The results show that although steel rebar has higher tensile strength, GFRP demonstrated competitive bond performance, particularly in aggressive environments. Observed failure patterns included pull-out failure and concrete splitting for both types of reinforcement. This research is expected to serve as
a reference for designing corrosion-resistant and environmentally friendly reinforced concrete
structures.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | GFRP, bond strength, pull-out test, flexural bonding, reinforced concrete, coastal |
Subjects: | 600 – ILMU TEKNIK DAN ILMU TERAPAN > 624 – Teknik Sipil dan Konstruksi > 624.2 – Struktur Bangunan dan Material |
Divisions: | Jurusan Teknik Sipil > Sarjana Terapan (D-IV) Teknik Perancangan Jalan dan Jembatan > SKRIPSI |
Depositing User: | D-IV TPJJ B 2021 |
Date Deposited: | 19 Aug 2025 06:56 |
Last Modified: | 19 Aug 2025 06:56 |
URI: | https://eprints.polbeng.ac.id/id/eprint/1982 |