Hafifi, Muhammad Faizal (2025) Studi Perbandingan Kinerja Akustik Pada Aliran Suhu Dengan Tambahan Material Alami dan Sintetis. Diploma thesis, Politeknik Negeri Bengkalis.
![[thumbnail of Abstract]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
TA-4103211416-Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (10kB)
![[thumbnail of Bab I Pendahuluan]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
TA-4103211416-Bab I Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (25kB)
![[thumbnail of Daftar Pustaka]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
TA-4103211416-Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.
Download (71kB)
![[thumbnail of Full Text]](https://eprints.polbeng.ac.id/style/images/fileicons/text.png)
TA-4103211416-Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.
Download (6MB) | Request a copy
Abstract
This study aims to analyze the comparison of indoor temperature conditions using natural and synthetic insulation materials. The research was conducted by measuring room temperature in a mushalla using an environment meter to observe temperature variations at different distances from the wall. The collected data were then validated and analyzed through Computational Fluid Dynamics (CFD) simulation using Workbench 2025 R1. The natural insulation material used was coco fiber, while the synthetic material was glass wool, both applied on brick wall layers.
Field measurements showed significant temperature fluctuations both indoors and outdoors. Simulation results indicated that natural and synthetic materials exhibit different performance in thermal resistance, with glass wool having a lower thermal transmittance coefficient (0.040 W/m²K) compared to coco fiber (0.045 W/m²K), affecting indoor temperature distribution. This research highlights the importance of selecting appropriate insulation materials to enhance energy efficiency and indoor thermal comfort in buildings.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | indoor temperature, thermal insulation, ANSYS, glass wool, coco fiber, CFD |
Subjects: | 600 – ILMU TEKNIK DAN ILMU TERAPAN > 624 – Teknik Sipil dan Konstruksi > 624.2 – Struktur Bangunan dan Material |
Divisions: | Jurusan Teknik Sipil > Diploma Tiga (D-III) Teknik Sipil > TUGAS AKHIR |
Depositing User: | D-III Teknik Sipil B 2022 |
Date Deposited: | 20 Aug 2025 05:19 |
Last Modified: | 20 Aug 2025 05:19 |
URI: | https://eprints.polbeng.ac.id/id/eprint/2350 |