Rancang Bangun Alat Pendeteksi Debu Untuk Sistem AC di Rumah Sakit

Yulianty, Merry (2025) Rancang Bangun Alat Pendeteksi Debu Untuk Sistem AC di Rumah Sakit. Other thesis, Politeknik Negeri Bengkalis.

[thumbnail of Abstract] Text (Abstract)
Skripsi - 3204211394 - Abstract.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (237kB)
[thumbnail of Bab I Pendahuluan] Text (Bab I Pendahuluan)
Skripsi - 3204211394 - Bab 1 Pendahuluan.pdf - Submitted Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (262kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Skripsi - 3204211394 - Daftar Pustaka.pdf - Submitted Version
Available under License Creative Commons Attribution Share Alike.

Download (199kB)
[thumbnail of Full Text] Text (Full Text)
Skripsi - 3204211394 - Full Text.pdf - Submitted Version
Restricted to Registered users only
Available under License Creative Commons Attribution Share Alike.

Download (2MB) | Request a copy

Abstract

Indoor air quality, particularly in hospital environments, is a crucial factor that affects both patient health and the comfort of medical personnel. Poorly monitored air conditioning (AC) systems can become a source of airborne dust particles, potentially leading to respiratory issues. Therefore, a device capable of monitoring temperature and dust concentration in real-time is essential to support air quality control.This research aims to design and develop a dust and temperature detection device for AC systems using the DHT22 temperature sensor, a Thermogun, and the GP2Y1010AU0F dust sensor. The DHT22 sensor is used for automatic temperature monitoring, while the Thermogun serves as a reference for temperature calibration. The GP2Y1010AU0F sensor is used to detect dust particle concentration in units of µg/m³. Sensor data is processed by a NodeMCU microcontroller, displayed on an LCD, and transmitted in real-time to the Blynk application as part of an IoT-based monitoring system.Test results show that the device is capable of responsively detecting changes in both temperature and dust levels. The DHT22 sensor showed a reading difference of approximately ±1°C compared to the Thermogun, while the GP2Y1010AU0F sensor recorded increased dust levels in response to nearby activity. This system is effective for real-time and efficient indoor air quality monitoring in hospital rooms.

Item Type: Thesis (Other)
Uncontrolled Keywords: AC, dust, temperature, DHT22, Thermogun, GP2Y1010AU0F, NodeMCU, IoT
Subjects: 600 – ILMU TEKNIK DAN ILMU TERAPAN > 625 – Teknik Kelistrikan dan Elektronik > 625.1 – Dasar-Dasar Listrik dan Elektronika
Divisions: Jurusan Teknik Elektro > Sarjana Terapan (D-IV) Teknik Listrik > SKRIPSI
Depositing User: D-IV Teknik Listrik Kelas A
Date Deposited: 21 Aug 2025 06:08
Last Modified: 21 Aug 2025 06:08
URI: https://eprints.polbeng.ac.id/id/eprint/2490